House wiring guide: cable sizes, protection and safety grades

Electrical material is a small share of project cost and the one place where cutting corners has consequences beyond money.

Last updated: 24 May 2026 · 6 min read

Sizing conductors

Typically 1.0–1.5 sq mm for lighting and fan circuits, 2.5 sq mm for general power sockets, 4.0 sq mm for air conditioners and geysers, and 6 sq mm and above for submains. Size from the actual connected load and run length, not habit.

Insulation grades

FR is flame retardant. FRLS adds low smoke. ZHFR is zero halogen — no corrosive gas at all. In a house fire, smoke and gas harm people before flame does. The cost difference across an entire home is small; specify FRLS as a minimum.

Protection

The MCB protects the cable, so it must be sized to the cable, not the appliance. Add RCCB or RCBO protection on socket and wet-area circuits — this is what prevents electrocution, and an MCB does not do it.

Earthing and conduit

A proper earth pit with a measured earth resistance, and a continuous earth conductor to every point. Use conduit heavy enough to survive being cast into a slab, and leave draw wires so future rewiring does not mean breaking walls.

The takeaway

Size cables from load, specify FRLS or better, protect with correctly sized MCBs plus RCCB, and earth properly.